10kN Strain Controlled Triaxial Apparatus
TKA-TTS-1S Strain controlled Triaxial Testing System Conforms to BS1377-7, 1377-8, 1924-2, ASTM D2850, D4767, AASHTO T296, T297 The detail info. as follow:
Item | Specifications | Qty |
1 | TKA cell for 35mm or 38mm diameter samples, which quasistatically controls axial displacement, comprising integral base unit housing axial actuator, control electronics, power supplies to drive same. Maximum cell pressure 2000 kPa. Maximum axial load 10kN. Including top caps and base pedestals for 35mm or 38mm samples plus all tubing and hydraulic connections. Infinitely variable speed from 0.00001 to9.99999mm/min | 1 |
2 | TKA load cell (10kN) including load ram, load button and electrical connection for TKA data interface | 1 |
3 | TKA pore pressure transducer 2MPawith electrical connection for TKA data interface. Accuracy 0.15% of Full Range Output | 1 |
4 | De-airing block and valve for pore pressure transducer | 1 |
5 | TKA two-channel RS232 Multiplexer (MUX), connects to RS232 port on PC | 1 |
6 | 1 of TKA 4-channel, 16bit data interface with RS232 interface. | 1 |
7 | TKA 2MPa/50cc Advanced digital pressure/volume controller with RS232 port, built in 16 key keypad and liquid crystal display, to give stand-alone or PC control Cell pressure/volume. Automatically protected against pressure and volume overange. Volume accuracy 0.1% of measured value. Pressure accuracy 0.15% of Full Range. Volume change measured and displayed to 1cu.mm (0.001cc). Pressure regulated and displayed to 1 kPa | 1 |
8 | TKA 2MPa/50cc Advanced digital pressure/volume controller with RS232 port, built in 16 key keypad and liquid crystal display, to give stand-alone or PC control Back pressure/volume. Automatically protected against pressure and volume overange. Volume accuracy 0.1% of measured value. Pressure accuracy 0.15% of Full Range. Volume change measured and displayed to 1cu.mm (0.001cc). Pressure regulated and displayed to 1 kPa | 1 |
9 | Test specimen preparation kits, 38mm/50mm Consisting of 3 part split former, 2 part split mould, suction sleeve stretcher, 20 membranes ,10 porous discs, 2 top discs | 1 set |
35mm test specimen preparation kit | 1 set | |
38mm test specimen preparation kit | 1 set | |
10 | Nylon Opaque Tubing.6mm OD.3500kPa.-5merters .The Nylon opaque tubing have an outer diameter of 6.0mm and inner diameter of 4.0mm.This tubing should be able to apply a pressure of 3500kPa | 1 |
10kN Strain Controlled Triaxial Apparatus